The new 500VA Victron Phoenix Inverter is an upgrade to the previous small inverters. As standard, it now includes a number of additional features, such as the VE.Direct port, making it far easier to communicate with the inverter.
VE.Direct communication port
The VE.Direct port can be connected to:
Fully configurable
Monitoring
In-and output voltage and current alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.
LED diagnosis
Please see manual for a description.
Automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Available with different output sockets
Schuko UK (BS-1363) AU/NZ (3112) EC-320 (male plug included)
Screw terminals
No special tools needed for installation
12 Volt | 12/250 |
12/375 |
12/500 |
24 Volt | 24/250 |
24/375 |
24/500 |
48 Volt | 48/375 |
48/500 |
|
Cont. power at 25°C | 250VA |
375VA |
500VA |
Cont. power at 25°C / 40°C | 200 / 175W |
300 / 260W |
400/350W |
Peak power | 400W |
700W |
900W |
Output AC voltage / frequency (adjustable) | 230VAC +/- 3% 50Hz or 60Hz +/- 0,1% |
||
Input voltage range | 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V |
||
DC low shut down (adjustable) | 9,3 / 18,6 / 37,2V |
||
Dynamic (load dependent) DC low shut down (adjustable) | Dynamic cut-off |
||
DC low restart and alarm (adjustable) | 10,9 / 21,8 / 43,6V |
||
Battery charged detect (adjustable) | 14,0 / 28,0 / 56,0V |
||
Max. efficiency | 87 / 88 / 88% |
89 / 89 / 90% |
90 / 90% |
Zero-load power | 4,2 / 5,2 / 7,9W |
5,6 / 6,1 / 8,5W |
6 / 6,5W |
Default zero-load power in ECO mode | 0,8 / 1,3 / 2,5W |
0,9 / 1,4 / 2,6W |
1 / 1,5 |
ECO mode stop and start power setting | > Adjustable |
||
Operating temperature range | -40 to +65°C (fan assisted cooling) |
||
Humidity (non-condensing) | max 95% |
||
ENCLOSURE | |||
Material & Colour | Steel chassis and plastic cover (blue Ral 5012) |
||
Battery-connection | Screw terminals |
||
Maximum cable cross-section | 10 mm² / AWG8 |
10 mm² / AWG8 |
10 mm² / AWG8 |
Standard AC outlets | 230V: Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
120V: Nema 5-15R |
||
Protection category | IP 21 |
||
Weight | 2,4kg / 5,3lbs |
3,0kg / 6,6lbs |
3,9kg / 8.5lbs |
Dimensions (hxwxd, mm) | 86x165x260 |
86x165x260 |
86x172x275 |
ACCESSORIES | |||
Remote on-off | Yes |
||
Automatic transfer switch | Filax |
||
STANDARDS | |||
Safety | EN/IEC 60335-1 / EN/IEC 62109-1 |
||
EMC | EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-32004/104/EC |
||
Automotive Directive | ECE R10-4 |
Our Off-grid experts will come back with recommendations