Our Run/Stop switch is a recommended for use with the LE-600 wind turbine. This high quality 3-pole cam actuated switch is designed to operate at the unusual voltages and currents generated by the turbine. It allows the turbine to be electrically isolated from the battery systems whilst also bringing the turbine to a near stop by placing a short circuit across the turbine output.

Due to the unique design of the alternators of our turbines, this short circuit, means that the alternator is put into ‘dynamic braking’ mode. The turbine will slow down until it is almost stationary and can then be moved out of the direction of the wind and lowered or tethered if it is stay mounted.

This switch acts as a temporary stop, not to be used to stop the turbine for long period.  The force of the wind can overcome the dynamic brake and the current generated is then circulated back into the stator causing the turbine to burn out.

The switch is supplied in a pre-assembled, compact enclosure making it easy to wire-in and mount. When installing, screw the terminal connections for 2.5mm cable

Your item has been added to your basket

Run/Stop Switch for LE-600 Wind Turbine

£74.82

£62.35 ex. VAT

Tell us about your project

Our Off-grid experts will come back with recommendations

Please leave your details and our experienced team will be in touch soon to assist you.
Please complete all required fields.
x
Can we help?
Leading Edge
Off-Grid Power Requirements
Please complete this form with your specific requirements and we would be happy to put together a bespoke off-grid power system. We will recommend a solution using our own British made wind turbines, best-in-class solar panels and deep-cycle batteries.

Contact Information

Once we have assessed your requirements, our experts will call you to discuss the equipment you'll need to achieve your goals.

What Is The Application?

Please tell us as much as you can about your use case. We understand that you may not be able to answer all questions. We will call you to discuss your requirements in any case.

Device Name
Voltage
Power Draw (W)
Peak Power Draw on Startup (W)
Standby Power (W)
Hours Active Per Day (W)
Days Per Week In Use (W)

Voltage Preference

Do you have a preference for the system voltage?

Outputs Required

Do you have a preference for the systems output?

Site Location

Please tell us a little bit about the site location

Other Details

No. of days autonomy required

Is there anything else we should know?

Leading Edge
Sign Up To Receive Our Newsletter

Stay up to date with Leading Edge innovations and offers by joining our mailing list. Occassionally we send informative newsletters, offers and promotions that we think you'll find useful or interesting.

Your Details

Please provide your contact details so that you can receive our newsletter. We will send this occassionally with information about our latest innovations and offers.