The 2000VA Victron MultiPlus inverter-charger is the most popular of the single AC output models, offering the flexibility of high power capacity and high charge currents. All MultiPlus inverter-charges combine a powerful true sine-wave inverter and advanced adaptive charger with a a high-speed AC transfer switch (12-millisecond changeover time).

High power & three-phase capabilities

Systems grow and change over time, so it is possible to connect up to 6 MultiPlus units together in parallel to achieve a higher output, for example six 2000W units can be linked to produce a 12.0kW system with six times the charging capacity. In addition, the MultiPlus can be used in ‘three-phase’ systems, where three units are used (one for each phase). This means that up to six sets of three inverter-chargers (18 in total) can be connected in parallel, producing 18 times the power output in 3-phases!

PowerControl - limited generator, shore side or grid power

Under certain circumstances, e.g. charging a completely flat battery bank, the MultiPlus can draw very large AC currents. When connected to a limited power shore-line or to a generator, the AC current can be limited to avoid overloading the generator or tripping the shore supply. The MultiPlus will also take the requirements of other AC loads into account, only using what is left to charge the batteries.

Twin AC output

All MultiPlus inverter-chargers of 3000W or greater now include two AC outputs. One of the outputs (AC1) is 'always on', meaning that appliances connected to it will always have AC power. The second output, however, is only active when the MultiPlus is connected to an AC supply (generators, shore-lines, etc), but will be switched off when only a DC supply from the battery banks is available. This configuration is ideal for when you have high current consumers, such as an immersion heater, that you would not want to power from your batteries, or where you wish to have only auxillary lighting when the mains grid fails. (All Quattro inverter-chargers include this feature).

PowerAssist - boosting the capacity of shore or generator power

Where the AC currents are limited by the capacity of the generator or shore-line, PowerAssist makes it possible to exceed the current limit by temporarily combining DC power from the battery bank. When the excessive load drops, the MultiPlus reverts back to using AC power again, using any surplus capacity to recharge the batteries.

UPS mode (Universal Power Supply)

When in UPS mode, the MultiPlus switches from AC to DC input power (in the event of a power failure, for example) in only 12-milliseconds. During this time, the voltage output only falls to 180VAC very briefly, allowing sensitive computer and communications equipment to continue operating.

Weak AC function

In certain circumstances, such as when using an old or unreliable generator, or in countries with unpredictable mains power, it may be necessary to activate the ‘weak AC’ option. When activated, the MultiPlus will operate with a much wider AC frequency and voltage range, although some efficiency is lost as a result. This is invaluable, especially in some of the Third World nations, where Victron equipment is often used for remote power supplies.

Four stage adaptive charger and dual battery bank charging

The main output charges the DC battery bank using advanced ‘adaptive charge’ software. The software fine-tunes the charge cycles to match the condition of the batteries, with a fourth stage for long periods of float charging. In addition to this, the 12V and 24V MultiPlus inverter-chargers have a supplementary trickle charge output which can be used to maintain the starter battery.

Simple system configuration

Nine times out of ten, it is not necessary to change any of the settings of the MultiPlus inverter-chargers, but if you wish to do so, this can be done very quickly using the new DIP switches, or by connecting the MultiPlus to your laptop and using the free VE.Configure software (available from the Victron website).

Your item has been added to your basket

Victron MultiPlus Inverter / Charger 2000VA 12/24V

£1079.95

£899.96 ex. VAT

Tell us about your project

Our Off-grid experts will come back with recommendations

Please leave your details and our experienced team will be in touch soon to assist you.
Please complete all required fields.
x
Can we help?
Leading Edge
Off-Grid Power Requirements
Please complete this form with your specific requirements and we would be happy to put together a bespoke off-grid power system. We will recommend a solution using our own British made wind turbines, best-in-class solar panels and deep-cycle batteries.

Contact Information

Once we have assessed your requirements, our experts will call you to discuss the equipment you'll need to achieve your goals.

What Is The Application?

Please tell us as much as you can about your use case. We understand that you may not be able to answer all questions. We will call you to discuss your requirements in any case.

Device Name
Voltage
Power Draw (W)
Peak Power Draw on Startup (W)
Standby Power (W)
Hours Active Per Day (W)
Days Per Week In Use (W)

Voltage Preference

Do you have a preference for the system voltage?

Outputs Required

Do you have a preference for the systems output?

Site Location

Please tell us a little bit about the site location

Other Details

No. of days autonomy required

Is there anything else we should know?

Leading Edge
Sign Up To Receive Our Newsletter

Stay up to date with Leading Edge innovations and offers by joining our mailing list. Occassionally we send informative newsletters, offers and promotions that we think you'll find useful or interesting.

Your Details

Please provide your contact details so that you can receive our newsletter. We will send this occassionally with information about our latest innovations and offers.